Key Data Set Information | |
Location | IT |
Geographical representativeness description | global |
Reference year | 2021 |
Name |
|
Use advice for data set | cradle to grave: A1, A2, A3, A4, A5, B1, B2, B3, B4, B5, B6, B7, C1, C2, C3, C4, D |
Technical purpose of product or process | The monolithic structure of the membrane guarantees excellent durability over time, thanks to the special polymers used. This Environmental Product Declaration (EPD) is valid for Air, wind and water barrier membranes and Vapor control layers designed by Rothoblass in Europe. Variable resistance to vapour diffusion: maximum protection for walls and excellent security in insulation. ENERGY RECONDITIONING Ideal to increase energy performancefor packages and solutions for re-conditioning of existing structures. REINFORCING GRID Thanks to its composition, the membrane is not affected by mechanical stresses caused by staples, nails or weare caused by walking. Composition: top layer - non woven PP fabric reinforcing layer - PE reinforcing grid middle layer - PA functional film bottom layer - non woven PP fabric |
General comment on data set | The data quality can be considered as good. The LCA models have been checked and most relevant flows were considered. Technological, geographical and temporal representativeness is appropriate. Information about single datasets is documented in http://database-documentation.gabisoftware.com/support/gabi/. EN 15804 requires that in case of data discrepancies or insufficient input data for a unit process, the cutoff criteria shall be 1% of renewable and non-renewable primary energy usage and 1% of the total mass of this unit process. The total neglected flows from a product stage must be no more than 5% of product inputs by mass or 5% of primary energy contribution. Production of capital equipment, facilities and infrastructure required for manufacture are outside the scope of this assessment. |
Copyright | Yes |
Owner of data set | |
Quantitative reference | |
Reference flow(s) |
|
Biogenic carbon content |
|
Time representativeness | |
Data set valid until | 2026 |
Technological representativeness | |
Technology description including background system | Mass per unit area: 160 g/m2 Water vapour transmission (Sd): 0,5-5 m Reaction to fire (steel): E Maximun tensile force MD/CD: 400-270 N/50mm Elongation MD/CD: 20-20 % Resistance to nail tearing MD/CD: 240-250 N |
Type of data set | EPD | ||||
Subtype | specific dataset | ||||
LCA methodology report | |||||
Data sources, treatment and representativeness | |||||
Documentation of data quality management | |||||
Data source(s) used for this data set | |||||
Completeness | |||||
Validation | |||||
| |||||
Compliance Declarations |
Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
Data generator | |
Data set generator / modeller |
|
Data entry by | |
Time stamp (last saved) | 2023-02-23T09:58:15 |
Data set format(s) | |
Publication and ownership | |
UUID | dc900061-388c-40c7-8f70-54c2d7d2da20 |
Date of last revision | 2023-02-23T08:57:26.9259352Z |
Data set version | 00.04.001 |
Registration authority |
EPDItaly
|
Registration number | EPDITALY0140 |
Owner of data set | |
Copyright | Yes |
License type | Free of charge for all users and uses |
Access and use restrictions | None |
|